The EL8020 Series provides media conversion between 10/100/1000BASE-TX and 100/1000 SFP Fiber. Built specifically for mission critical applications in harsh environments, the EL8020’s hardened design features high shock & vibration resistance, electrical noise immunity, wide operating temperature range from -40 to 75°C (-40 to 167°F), and aluminum housing. With two power inputs, link down alarming, Link-Fault-Pass-Through and a wide range of fiber connectivity options, the EL8020 is the ideal media converter for environments where connectivity is crucial.
Technology
- Standards
- • IEEE 802.3 10BASE-T
- • IEEE 802.3u 100BASE-TX
- • IEEE 802.3ab 1000BASE-T
- Forward and Filtering Rate
- • 14,880pps for 10Mbps
- • 148,810pps for 1000Mbps
- • 1,488,100pps for 1000Mbps
- Processing Type
- • Auto Negotiation
- • Auto MDI/MDIX
Power
- Input
- • 12-48VDC
- Power Consumption
- • 0.912W Max, 76mA@12VDC, 38mA@24VDC, 19mA@48VDC
- Protection
- • Overload Current Protection
- • Reverse Polarity Protection
Mechanical
- Casing
- • Aluminum Case
- • IP30
- Dimensions
- • 35.8 x 90 x 100mm (W x D x H)
(1.41″ x 3.54″ x 3.94″)
- Weight
- • 0.23Kg (0.51lbs.)
- Installation
- • DIN-Rail
Interface
- Ethernet Port
- • 10/100/1000BASE-TX: 1 port
- • 100/1000 SFP: 1 port
- LED Indicators
- • Per Unit: Power 1, Power 2, Fault, LFPT
- • Per Port: Link/Activity
- DIP Switch
- • No.1: LFPT On/Off
- • No.2: Alarm for copper port On/Off
- • No.3: Alarm for fiber port On/Off
- • No.4: Auto-negotiation for fiber port On/Off
- Alarm Contact
- • Relay contact rating with current 0.6A/30VDC
Environment
- Operating Temperature
- • -40 to 75°C (-40 to 167°F)
- Storage Temperature
- • -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity
- • 5% to 95% (non-condensing)
Regulatory Approvals
- ISO
- • Manufactured in an ISO 9001 facility
- Safety
- UL 61010
- Industrial Compliance
- EN 50121-4
- EMI
- FCC Part 15B Class A
- VCCI Class A
- EN 55032
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-6-3
- EMS
- EN 61000-6-2
- • EN 61000-4-2 (ESD Standards)
- • EN 61000-4-3 (Radiated RFI Standards)
- • EN 61000-4-4 (Burst Standards)
- • EN 61000-4-5 (Surge Standards)
- • EN 61000-4-6 (Induced RFI Standards)
- • EN 61000-4-8 (Magnetic Field Standards)
- Environmental Test Compliance
- IEC 60068-2-6 Fc (Vibration Resistance)
- IEC 60068-2-27 Ea (Shock)
- FED STD 101C Method 5007.1 (Free fall w/package)